Power Supply:
Voltage: 12 Volts
-----------------------------------------------------------
PS Model Input Power Current Status
Type (Watts) (Amps)
-----------------------------------------------------------
1 -- -- -- -- fail/not-powered-up
2 N2200-PAC-400W-B AC 396.00 33.00 ok
ID
Power Supply:
Voltage: 12 Volts
-----------------------------------------------------------
PS Model Input Power Current Status
Type (Watts) (Amps)
-----------------------------------------------------------
1 -- -- -- -- fail/not-powered-up
2 N2200-PAC-400W-B AC 396.00 33.00 ok
DL
ID
show environment power input
DL
Power Supply Input:
----------------------------------------------------------
PS Voltage Current Power Status
(Volt) (Amp) (Watt)
----------------------------------------------------------
1 -- -- -- absent
2 232.00 0.62 145.00 ok
----------------------------------------------------------
DL
ID
Power Supply Input:
----------------------------------------------------------
PS Voltage Current Power Status
(Volt) (Amp) (Watt)
----------------------------------------------------------
1 -- -- -- absent
2 232.00 0.62 145.00 ok
----------------------------------------------------------
ID
Power Supply Input:
----------------------------------------------------------
PS Voltage Current Power Status
(Volt) (Amp) (Watt)
----------------------------------------------------------
1 -- -- -- absent
2 232.00 0.62 145.00 ok
----------------------------------------------------------
DL
2020 Nov 17 19:14:12 M9-NXS1 %PLATFORM-2-PS_DETECT: Power supply 1 detected but shutdown (Serial number LIT17110FK4)
2020 Nov 17 19:14:12 M9-NXS1 %PLATFORM-5-PS_STATUS: PowerSupply 1 current-status is PS_SHUT
2020 Nov 17 19:14:12 M9-NXS1 %PLATFORM-2-PS_CAPACITY_CHANGE: Power supply PS1 changed its capacity. possibly due to On/Off or power cable removal/insertion (Serial number
LIT17110FK4)
2020 Nov 17 19:14:12 M9-NXS1 %PLATFORM-2-PS_ABSENT: Power supply 1 is absent/shutdown, ps-redundancy might be affected
2020 Nov 17 19:14:12 M9-NXS1 %PLATFORM-2-PS_RED_MODE_CHG: Power supply operational redundancy mode changed to non-redundant
2020 Nov 17 19:25:42 M9-NXS1 %PLATFORM-5-PS_FOUND: Power supply 1 found (Serial number LIT17110FK4)
2020 Nov 17 19:25:42 M9-NXS1 %PLATFORM-2-PS_OK: Power supply 1 ok (Serial number LIT17110FK4)
2020 Nov 17 19:25:42 M9-NXS1 %PLATFORM-5-PS_STATUS: PowerSupply 1 current-status is PS_OK
2020 Nov 17 19:25:42 M9-NXS1 %PLATFORM-2-PS_FANOK: Fan in Power supply 1 ok
2020 Nov 17 19:25:42 M9-NXS1 %PLATFORM-2-PS_CAPACITY_CHANGE: Power supply PS1 changed its capacity. possibly due to On/Off or power cable removal/insertion (Serial number
LIT17110FK4)
2020 Nov 17 19:25:42 M9-NXS1 %PLATFORM-4-PFM_PS_RED_MODE_CHG: Power redundancy configured mode changed to ps-redundant
2020 Nov 17 19:25:42 M9-NXS1 %PLATFORM-2-PS_RED_MODE_RESTORED: Power redundancy operational mode changed to configured mode
2020 Nov 17 19:29:30 M9-NXS1 %PLATFORM-2-PS_DETECT: Power supply 1 detected but shutdown (Serial number LIT17110FK4)